Appendix B — Default Settings
PC23 and PC43 Desktop Printer User Manual 149
Media Length Sets the length of the printable area
measured from one edge of the label to the
edge that is closest to the printhead. Unit of
measurement is defined in the Unit of
Measurement parameter.
Variable
Clip Default Determines if the printer prints items
outside the printable area of the label.
When this is set to Off, the printer returns
an error if any part of a bar code label
cannot be printed because that part extends
beyond the printable area. When this is set
to On, the printer prints all bar code labels,
but may also print unreadable, incomplete
labels.
Off
Start Adjust Sets the length of media the printer feeds
(positive value) or retracts (negative value)
before printing a label. Unit of
measurement is defined in the Unit of
Measure parameter. Range is -9999 to
+9999.
0
Stop Adjust Sets the length of media the printer feeds
(positive value) or retracts (negative value)
after printing a label. Unit of measurement
is defined in the Unit of Measure parameter.
Range is -9999 to +9999.
0
Media
Calibration
Mode
Selects the mode the printer uses to
calibrate media. Use Slow if the printer has
trouble identifying gaps or marks in media.
Fast
Media Settings (Continued)
Setting Description Default