SOURce Subsystem
Arguments
<NRf+>
MINimum|MAXimum|DEFault|<value>
Setting range: MIN~MAX
Default Value
None
Example
VOLT:UND:PROT:WARM 5
Query Syntax
[SOURce:]VOLTage:UNDer:PROTection:WARM?
Returns
<NRf+>
12.20 [SOURce:]RESistance[:LEVel][:IMMediate][:
AMPLitude] <NRf+>
This command is used to set the input resistance value in CR operation mode.
Group
SOURce
Syntax
[SOURce:]RESistance[:LEVel][:IMMediate][:AMPLitude] <NRf+>
Arguments
<NRf+>
MINimum|MAXimum|DEFault|<value>
Setting range: MIN to MAX