SOURce Subsystem
Query Syntax
[SOURce:]POWer[:LEVel][:IMMediate][:AMPLitude]?
Returns
<NRf+>
12.22 [SOURce:]POWer:PROTection:STATe
<bool>
Enable or disable over power protection. If power protection is enabled and the
input reaches the power limit, the input is disabled.
Group
SOURce
Syntax
[SOURce:]POWer:PROTection:STATe <bool>
Arguments
<Bool>
0|OFF|1|ON
Default Value
0|OFF
Example
POW:PROT:STAT 1
Query Syntax
[SOURce:]POWer:PROTection:STATe?
Returns
0|1