TRIGger Subsystem
TRIGger:ACQuire:VOLTage:HYSTeresis:HIGH
<NRf+>
This command is used to set the voltage trigger high threshold.
Group
TRIGger
Syntax
TRIGger:ACQuire:VOLTage:HYSTeresis:HIGH <NRf+>
Arguments
<NRf+>
MIN|MAX|DEF|<value>
Setting range: MIN to MAX
Default Value
MIN
Example
TRIGger:ACQuire:VOLTage:HYSTeresis:HIGH 100
Query Syntax
TRIGger:ACQuire:VOLTage:HYSTeresis:HIGH? [MIN|MAX|DEF]
Returns
<NRf+>
MIN|MAX|DEF|<value>
TRIGger:ACQuire:VOLTage:HYSTeresis:LOW
<NRf+>
This command is used to set the voltage trigger low threshold.