CONFigurable Subsystem
0 to 6
Default Value
None
Returns
<CRD>
OFFSta|PSSTa|INHLiv|EXTTrig|SYON|SYOFF|INHLat|IORD|IOWR|PSCLear|
PWM|TOUT
Example
IO:TYPE? 1
Also see
None
[CONFigurable:]IO:TRIGger:TYPE <CPD>
This command is used to set the Ext-Trig function type of pin 4:
TOUT: When the instrument generates a trigger signal (trigger Meter, data
logging or List function running), a pulse signal will be output from pin 4;
TIN: Indicates that the instrument will trigger the running of the Meter func-
tion, data logging function or List function after receiving a pulse signal from
the outside.
Group
CONFigurable
Syntax
[CONFigurable:]IO:TRIGger:TYPE <CPD>
Arguments
<CPD>
TOUT|TIN
Copyright © Itech Electronic Co., Ltd.