Chapter 8 SAMComplete Testing
Specifying settings
232
HST-3000 Ethernet Testing User’s Guide
3 From the SAMComplete Settings list, select Global
Settings and then specify the following settings:
4 If running a multi-stream application, select Service
Select, and then specify which services should be tested.
5 Select one of the following:
– If running a single-stream application, select Service
Settings.
– If running a multi-stream application, select All
Services.
Setting Description Parameters
Configuration Test Select whether to run the service
configuration test.
On, Off
Config Test Steps The number of steps below CIR. 1 - 10
Step Duration The duration that traffic is gener-
ated for each step.
1 - 60 sec
Performance Test Select whether to run the service
performance test.
On, Off
Perf Test Duration The duration that traffic is gener-
ated before the service perfor-
mance test completes
1 - 1440 min
Stop on Failure Select whether to stop the test
when a failure occurs or continue
through to completion.
Yes, No
Customer, Techni-
cian, Location, and
Comments
If you want them to appear in the
report output, enter the customer
name, technician name, test loca-
tion, and comments about the test.
Alphanumeric up
to 25 characters