Chapter 8 SAMComplete Testing
Specifying settings
236
HST-3000 Ethernet Testing User’s Guide
Then specify the following settings:
Setting Parameters
Service Number
(multi-stream applica-
tion only)
Select which service to configure:
1-8
Service Name Enter the name of the service.
Source Type
(L2 single stream
applications only)
Factory default
User defined (and enter the
MAC address)
Tx Payload
(single-stream appli-
cation only)
Acterna or BERT
(Always select Acterna for SAM-
Complete test)
Pattern (if Tx Payload
is BERT)
Specify which BERT pattern to
use for the test.
Acterna Payload (if Tx
Payload is Acterna)
Specify whether the Acterna Pay-
load is Fill pattern or BERT.
Fill Pattern (if Acterna
Payload is Fill Pat-
tern)
Specify the fill byte using hexa-
decimal format, up to 64 bytes.
Loop Type
(L2 applications only)
Unicast - sends traffic to a
single destination address
and network device.
Broadcast - sends traffic to all
network devices on the link.
NOTE: If you select Unicast,
you can optionally use the
Discover soft key to discover
other instruments on the net-
work, and then select the
destination address for the
device you want to transmit
traffic to. For details, see
“Using J-Connect to discover
another JDSU test set” on
page 21

Table of Contents