Appendix A Test Results
Link Counts results
HST-3000 Ethernet Testing User’s Guide
277
Rx Collisions A count of the number of times the HST
has received a jam signal while it was
not transmitting frames. Result only
appears for half-duplex 10/100 Ether-
net tests.
Rx Frame Bytes A count of the total bytes received
within an Ethernet frame from the Des-
tination MAC Address to the FCS,
inclusive.
Rx Frames A count of all frames received meeting
filter criteria since starting the test.
Rx Frames ALL A count of frames received since start-
ing the test, including errored frames.
Frames do not need to satisfy filter cri-
teria to be included in this count.
Rx IP Packets A count of IP packets received since
starting the test.
Rx L4 Destination
Port
Displays the Destination Port number
for the last layer 4 frame received.
Rx L4 Source Port Displays the Source Port number for
the last layer 4 frame received.
Rx QinQ Frames A count of Q-in-Q encapsulated frames
received since starting the test, exclud-
ing errored frames.
Rx Router Adv. Msg. A count of received router advertise-
ment messages when running an IPv6
application. This count is not reset
when you restart a test; to reset the
count you must bring down the link,
reestablish the link, and then start the
test again.
Rx TCP Packets A count of TCP packets received since
starting the test, excluding errored
frames since starting the test.
Table 22 Link Counts test results (Continued)
Result Description