Safety information for Floor-Spot with blue light
CAUTION!
Risk of retinal damage due to blue light
The Floor-Spot on the truck is classified in risk group 2 according to the standard
IEC 62471: medium risk. In the range of 400 nm to 780 nm, blue light can potentially
damage the retina of the human eye.
u
Check that the warning notice: "Caution! Potentially dangerous optical radiation" is
present and legible, and replace if necessary.
u
Do not look directly into the light beam of the Floor-Spot.
u
When performing maintenance and repairs, take the Floor-Spot out of service, e.g.
by disconnecting the battery, and secure it against unintentional recommissioning.
Z
The warning notice (245) is attached to the overhead guard or
mast next to the Floor-Spot. An additional, smaller warning
notice (245) is attached to the Floor-Spot.
312