3 Exposing the battery
WARNING!
An unsecured truck can cause accidents
Parking the truck on an incline or with a raised load handler is dangerous and is
strictly prohibited.
u
Park the truck on a level surface. In special cases the truck may need to be
secured with wedges.
u
Fully lower the load handler.
u
Select a place to park where no other people are at risk of injury from the lowered
load handler.
u
If the brakes are not working, place wedges underneath the wheels of the truck to
prevent it from moving.
NOTICE
The truck must not be parked on transport or escape routes, in front of safety
installations, or in front of factory equipment that must be accessible at all times.
9
8
97
98
29
Opening the battery panel
Requirements
– Park the truck securely, see page 191.
Procedure
• Lower the load handler to the ground, see page 171.
• Switch off the truck, to do this:
• Turn the key in the key switch (8) to the left as far as the stop and remove the
key.
•
Press the red button of the ISM access module (o) twice in a row.
• Press the emergency disconnect switch (9).
76
04.19 en-GB

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jungheinrich EFX 413 and is the answer not in the manual?

Jungheinrich EFX 413 Specifications

General IconGeneral
BrandJungheinrich
ModelEFX 413
CategoryTrucks
LanguageEnglish

Related product manuals