02.16 EN
28
Cleaning the battery with a high pressure cleaner
Requirements
– Cell connectors tight, plugged in securely
– Cell plugs closed
Procedure
• Follow the high pressure cleaner's user instructions.
• Do not use any cleaning additives.
• Observe the permissible cleaning device temperature setting of 140°C.
Z This generally ensures that the temperature does not exceed 60°C at a distance of
30cm behind the outlet nozzle.
• Observe the maximum operating pressure of 50 bar.
• Observe a minimum distance of 30 cm from the top of the battery.
• The battery should be sprayed over its entire surface to avoid localised
overheating.
Z Do not clean one spot for more than 3 seconds with the jet to avoid exceeding the
maximum battery surface temperature of 60°C.
• After cleaning dry the battery surface with suitable materials e.g. compressed air or
cleaning cloths.
Battery cleaned.