Figure 37: Mounting the Switch on Two Posts of a Rack
8. Have a second person secure the switch to the rack by using the appropriate screws.
Tighten the screws.
9. Ensure that the switch chassis is level by verifying that all screws on one side of the
rack are aligned with the screws on the other side.
Related
Documentation
Mounting an EX2300 Switch on Four Posts of a Rack or Cabinet on page 137
Connecting Earth Ground to an EX Series Switch on page 155
Connecting AC Power to an EX2300 Switch on page 161
Connecting DC Power to an EX2300 Switch on page 163
Connecting and Configuring an EX Series Switch (CLI Procedure) on page 179
Connecting and Configuring an EX Series Switch (J-Web Procedure) on page 182
Mounting an EX2300 Switch in a Recessed Position in a Rack or Cabinet on page 153
Rack-Mounting and Cabinet-Mounting Warnings on page 234
Mounting an EX2300 Switch on Four Posts of a Rack or Cabinet
You can mount an EX2300 switch except the EX2300-C switch model on four posts of
a 19-in. rack or cabinet by using the separately orderable four-post rack-mount kit. The
remainder of this topic uses rack to mean rack or cabinet.