EasyManua.ls Logo

Juniper EX2300-C - Page 77

Juniper EX2300-C
294 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 30: EX Series Switch Environmental Tolerances (continued)
Environment Tolerance
Switch or
device SeismicTemperatureRelative HumidityAltitude
Designed to comply
with Zone 4
earthquake
requirements per
NEBS GR-63-CORE,
Issue 4.
Normal operation ensured in
the temperature range 32° F
(0° C) through 113° F (4 C)
Nonoperating storage
temperature in shipping
container: –40° F (–40° C)
through 158° F (70° C)
Normal operationensured in
the relative humidity range
5% through 90%,
noncondensing
Short-term operation
ensured in the relative
humidity range 5%
through 93%,
noncondensing
NOTE: As defined in
NEBS GR-63-CORE, Issue
4, short-term events can
be up to 96 hours in
duration but not more
than 15 days per year.
No performance
degradation to
6,562 feet
(2000 meters)
EX4600
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation is ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Normal operationensured in
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX6210
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation is ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Normal operationensured in
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX8208
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation is ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Normal operationensured in
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX8216
Complies with Zone 4
earthquake
requirements as per
GR-63.
Normal operation is ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Nonoperating storage
temperature in shipping
container: –40° F (–40° C) to
158° F (70° C)
Normal operationensured in
the relative humidity range
5% through 90%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX9204
Complies with Zone 4
earthquake
requirements as per
GR-63.
Normal operation is ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Nonoperating storage
temperature in shipping
container: –40° F (–40° C) to
158° F (70° C)
Normal operationensured in
the relative humidity range
5% through 90%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX9208
55Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Preparation Overview

Table of Contents

Other manuals for Juniper EX2300-C

Related product manuals