Never install electrical jacks in wet locations unless the jacks are specifically designed
for wet environments.
Operate the device only when it is properly grounded.
Ensure that the separate protective earthing terminal provided on this device is
permanently connected to earth.
Replace fuses only with fuses of the same type and rating.
Do not open or remove chassis covers or sheet-metal parts unless instructions are
provided in the hardware documentation for this device. Such an action could cause
severe electrical shock.
Do not push or force any objects through any opening in the chassis frame. Such an
action could result in electrical shock or fire.
Avoid spilling liquid onto the chassis or onto any device component. Such an action
could cause electrical shock or damage the device.
Avoid touching uninsulated electrical wires or terminals that have not been
disconnected from their power source. Such an action could cause electrical shock.
Always ensure that all modules, power supplies, and cover panels are fully inserted
and that the installation screws are fully tightened.
Related
Documentation
AC Power Electrical Safety Guidelines on page 160
DC Power Electrical Safety Guidelines on page 162
General Electrical Safety Guidelines and Warnings on page 157
Maintenance and Operational Safety Guidelines and Warnings on page 151
Laser and LED Safety Guidelines and Warnings for EX Series Switches on page 139
Installation Instructions Warning on page 143
Grounded Equipment Warning on page 150
Laser and LED Safety Guidelines and Warnings for the QFX Series
Definitions of Safety Warning Levels
This topic applies to hardware devices in the EX Series product family, which includes
switches and the XRE200 External Routing Engine.
This topic also applies to hardware devices in the QFX Series.
The documentation uses the following levels of safety warnings (there are two “Warning”
formats):
NOTE: You might find this information helpful in a particular situation, or you
might overlook this important information if it was not highlighted in a Note.
Copyright © 2011, Juniper Networks, Inc.134
Complete Hardware Guide for EX3300 Ethernet Switches

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX3300 Series and is the answer not in the manual?

Juniper EX3300 Series Specifications

General IconGeneral
Layer SupportLayer 2 and Layer 3
JUNOS OSYes
Ports24 or 48 x 10/100/1000BASE-T ports
Uplink Ports4 x 1GbE/10GbE SFP/SFP+ ports
Power SupplyAC or DC options
StackingYes, up to 10 units
MAC Address Table Size32, 000
Operating Humidity10% to 90% non-condensing
PoE SupportAvailable on PoE models
Virtual ChassisYes, up to 10 units
Operating Temperature32° to 104° F (0° to 40° C)