To prevent the Reset Config button from setting the device to the factory default
configuration and deleting all other configurations:
admin@host# set chassis config-button no-clear
You can still press and quickly release the button to reset it to the rescue configuration.
•
To prevent the Reset Config button from setting the device to the rescue configuration:
admin@host# set chassis config-button no-rescue
You can still press and hold the button for 15 seconds or more to reset the gateway to
the factory defaults.
•
To disable the button and prevent the device from resetting to either configuration:
admin@host# set chassis config-button no-clear no-rescue
The no-clear option prevents the Reset Config button from deleting all configurations
on the services gateway. The no-rescue option prevents the Reset Config button from
loading the rescue configuration.
To return the function of the Reset Config button to its default behavior, remove the
config-button statement from the device configuration.
Related
Documentation
Using the Reset Config Button on the SRX210 Services Gateway on page 121•
• Monitoring the SRX210 Services Gateway Chassis Using the CLI on page 113
• Monitoring the SRX210 Services Gateway Components Using LEDs on page 115
• Monitoring the SRX210 Services Gateway Using Chassis Alarm Conditions on page 118
• Monitoring the SRX210 Services Gateway Power System on page 119
• Juniper Networks Technical Assistance Center on page 122
Juniper Networks Technical Assistance Center
If you need assistance while troubleshooting a services gateway, open a support case
using the Case Manager link at http://www.juniper.net/support/ , or call 1-888-314-JTAC
(within the United States) or 1-408-745-9500 (from outside the United States).
Copyright © 2010, Juniper Networks, Inc.122
SRX210 Services Gateway Hardware Guide