©2015 KCM Corporation. All rights reserved. Printed in Japan (K)
(アメリカ用)
93108-00691
April 2015
OPERATION &
MAINTENANCE MANUAL
WHEEL LOADER
70Z7/70TM7
Powered by CUMMINS QSB6.7 Engine
Serial No. 70C6-5001 and up
NOTICE
READ AND UNDERSTAND THIS
MANUAL BEFORE OPERATING
AND SAVE THIS MANUAL ON
THE MACHINE
70Z7/70TM7 93108-00691

Table of Contents

Questions and Answers

  • T
    Tammy WolfeAug 7, 2025
    What to do if coolant temperature is too high in KCM Front End Loaders?
    • M
      markwellsAug 7, 2025
      If the coolant temperature is too high in your KCM Front End Loaders, there are several possible causes and solutions: * Check and add coolant if the level is low. * Adjust or repair the fan if its operation is abnormal. * Replace a damaged rubber hose or a faulty thermostat. * Replace a faulty coolant temperature gauge. * Flush the cooling system if the passages are dirty. * Clean the radiator and oil cooler if their cores are plugged. * Clean the radiator screen if it's plugged.
  • M
    mark35Aug 17, 2025
    Why won't the starter turn in my KCM 70Z7 Front End Loaders?
    • M
      maldonadolauraAug 17, 2025
      If the starter does not turn in your KCM Front End Load Loaders, consider these potential causes and solutions: * Charge or replace batteries if the voltage is reduced. * Clean and/or retighten the battery and starter terminals if there's high resistance in the starter circuit. * Replace a faulty key switch or battery relay. * Repair or replace a damaged wire harness or a faulty starter. * Replace a blown slow blow fuse link. * Return the forward/reverse selector lever to neutral. * Turn the battery disconnect switch to the ON position.
  • C
    christinediazAug 28, 2025
    How to fix batteries that will not charge in KCM Front End Loaders?
    • H
      Henry JacobsAug 28, 2025
      If the batteries in your KCM Front End Loaders will not charge, consider the following possible causes: * A broken battery separator, which requires replacement. * A faulty regulator, which requires adjustment or replacement. * A faulty ground line, which needs repair. * A faulty alternator, which needs repair or replacement.