Features and Functions
81150A and 81160A User’s Guide 173
Define the next
waveform point
Press the Point # softkey and then turn the knob to move to Point #2, or
press the Next Point softkey.
Press the X softkey to set the address for the current point (this softkey is
not available for Point #1). Press the Y softkey to set the DAC value for the
current point.
For this example, Y to -8191. Then press the Next Point softkey to proceed
to the next point in the waveform.
Define the
remaining
waveform points
Using the X and Y softkeys, define the remaining waveform points using the
values shown in the table below.
The X value of the last point that can be defined in each bit transition
must be less than (64 ×bit# -1). With bit# being the zero based index
of the transition that contains the current point.
The X value cannot be changed for the first point of each transition
definition. These points are marked by the vertical dashed white
lines.
To insert additional points after the current waveform point, press the
Insert Point softkey. The new point is inserted with the same DAC
value as the current point.
To remove the current waveform point, press the Remove Point
softkey. The remaining points are joined using the interpolation
method currently selected.
If Point #1 is removed, then Point #2 will be placed to address 0.
Remove Point is not possible if the waveform has 2 points, since this
is the minimum waveform length.