Features and Functions
81150A and 81160A User’s Guide 249
Define the first
waveform point
Press Y softkey to set the voltage level for Point #1 (this point is fixed at
address 0). By default, all points are set to 0.
For this example, set the value of Point # 1 to -8191.
Define the next
waveform point
Press the Point # softkey and then turn the knob to move to Point #2, or
press the Next Point softkey.
Press the X softkey to set the address for the current point (this softkey is
not available for Point #1). Press the Y softkey to set the DAC value for the
current point.
For this example, set X to 3279 and Y to 8191.