Define the
remaining
waveform points
Using the X and Y softkeys, define the remaining waveform points using the
values shown in the table below.
The X value of the last point that can be defined in the waveform
must be less than 16384 (16K).
The waveform editor automatically connects the last waveform point
to the voltage level of first point to create a continuous waveform.
To insert additional points after the current waveform point, press the
Insert Point softkey. The new point is inserted with the same DAC
value as the current point.
To remove the current waveform point, press the Remove Point
softkey. The remaining points are joined using the interpolation
method currently selected.
If Point #1 is removed, then Point #2 will be placed to address 0.
Remove Point is not possible if the waveform has 2 points, since this
is the minimum waveform length.
Point
X
Y
1
0
-8191
2
3279
8191
3
6554
4096
4
11469
-8191
Equidistant Spacing
Pressing the [Equidistant Spacing] softkey adjusts all points in the waveform
editor at an equal distance from one-another.