2NM/2NX/2NY/2NZ/2P0/2P6
1-3-82
U640 Comm Time 1
Description
Sets the detection time when one-shot detection is selected for remote switching. (This setting
item will be displayed, but the setting made is ineffective.)
Sets the detection time when continuous detection is selected for remote switching. (This setting
item will be displayed, but the setting made is ineffective.)
Purpose
The decision system of a remote change is set up to compensate for a user's telephone classifica-
tion, peculiarity, etc.
Method
1. Press the start key.
2. Select the item to be set.
3. Change the setting using the cursor right/left keys.
Display Description Setting range Initial setting
Time(One) Sets the one-shot detection time for remote
switching.
0 to 255 7
Time(Cont) Sets the continuous detection time for remote
switching.
0 to 255 80
4. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.