2NM/2NX/2NY/2NZ/2P0/2P6
1-4-117
U01040 A DCN or other inappropriate signal was received during standby for DIS signal recep-
tion.
U01041 A DCN signal was received after transmission of a DNL (MPS or EOM) signal (between
units of our make).
U01042 A DCN signal was received after transmission of a DCS, TCF signal.
U01043 A DCN signal was received after transmission of an NSS1, NSS2 (TCF) signal (between
units of our make).
U01044 A DCN signal was received after transmission of an NSS3, TCF signal (between units of
our make).
U01045 A DCN or other inappropriate signal was received after transmission of an MPS signal.
U01046 A DCN or other inappropriate signal was received after transmission of an EOM signal.
U01047 A DCN or other inappropriate signal was received after transmission of an EOP signal.
U01048 A DCN signal was received after transmission of a PRI-EOP signal.
U01049 A DCN signal was received after transmission of a CNC signal (between units of our
make).
U01050 A DCN signal was received after transmission of a CTC signal (ECM).
U01051 A DCN signal was received after transmission of an EOR.Q signal (ECM).
U01052 A DCN signal was received after transmission of an RR signal (ECM).
U01053 A DCN signal was received after transmission of a PPS.NULL signal (ECM).
U01054 A DCN signal was received after transmission of a PPS.MPS signal (ECM).
U01055 A DCN signal was received after transmission of a PPS.EOM signal (ECM).
U01056 A DCN signal was received after transmission of a PPS.EOP signal (ECM).
U01057 A DCN signal was received after transmission of a PPS.PRI-EOP signal (ECM).
U01070 Polarity reversal was detected during handshake.
U01071 Polarity reversal was detected during message transmission.
U01072 A break in loop current was detected during transmission.
U01073 During reverse polling in V.34 mode at the receiver unit, a CM signal was not detected
when transmitting after reception.
U01080 A PIP signal was received after transmission of a PPS.NULL signal.
U01091 During transmission in V.34 mode, communication was interrupted because a PPR sig-
nal was received over 10 times even after reducing the communication speed to the min-
imum with the symbol speed maintained at the level of connection.
U01092 During transmission in V.34 mode, communication was interrupted because of an impos-
sible combination of the symbol speed and communication speed.
Error code Description

Table of Contents

Other manuals for Kyocera ECOSYS M3540dn

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kyocera ECOSYS M3540dn and is the answer not in the manual?

Kyocera ECOSYS M3540dn Specifications

General IconGeneral
BrandKyocera
ModelECOSYS M3540dn
CategoryAll in One Printer
LanguageEnglish

Related product manuals