IMPULSE•G+ Mini Advanced Instruction Manual – March 2014
5-49
59 Alternate Upper
Frequency
Alternate Reference Upper
Limit Frequency
5-5 Basic/Adv
5A Maintenance Reset Reset Maintenance Timer
(C12.05 - C12.06, U01.52)
5-33 Adv
5B BE6 Up Speed Limit Limit Fref to C08.17 (BE6 Up
Speed Limit)
-- Adv
5F Phantom Fault N.C. Stops motion based C03.09 but
does not change Keypad
display. Stop L.E.D. on JVOP
blinks
5-21 Adv
62 Weight Limit N.O. Weighted Upper Limit (UL3).
Stopping Method determined by
C03.08
5-20 Adv
63 Phantom Fault N.O. Stops motion based C03.09 but
does not change Keypad
display. STOP L.E.D. on JVOP
blinks
5-21 Adv
65 Dwell Enable Enables/Disables Dwell
function. When H01.0X = 65H,
OFF = Disabled.
5-39 Adv
69 LC Disable When the input is active, the
Load Check function will be
disabled.
-- Adv
70 Torque Detection When H01.0X = 70H,
Overtorque/Undertorque
detection is enabled and
disabled by MFDI. When the
input is closed, Overtorque/
Undertorque detection is
enabled
-- Adv
80 Forward Run. Forward Run Command 5-4 Basic/Adv
81 Reverse Run Reverse Run Command 5-4 Basic/Adv
Parameter
Code Name Function
Reference
Page
Number Range
Initial
Value
Access
Level
* = Parameter defaults changed by X-Press Programming