IMPULSE•G+ Mini Advanced Instruction Manual – March 2014
5-52
015 Freq Detect 3 Closed when output frequency

L04.03
5-72 Adv
016 Freq Detect 4. Closed when output frequency
L04.03
5-72 Adv
017 Trq Det 1 N.C. Open when torque > L06.02
for longer than L06.03 time
5-75 Basic/Adv
018 Trq Det 2 N.O. Closed when torque > L06.05 5-76 Adv
019 Trq Det 2 N.C. Open when torque > L06.05 5-76 Adv
01A Forward Direction Closed when running FWD/
UP
-- Adv
01B Reverse Direction Closed when running REV/
DOWN
-- Adv
01C Swift Active Closed when Swift Lift is
active
5-26 Adv
01DBaseBlk N.C. Open during baseblock 2 -- Adv
020 Auto-Rst Attempt Closed when auto reset is
enabled
5-78 Adv
021 Overload OL1 Closed when an OL1
Overload fault code occurs
5-63 Adv
022 Overheat Prealarm Closed when “OH” is
displayed on keypad
5-77 Adv
023 Torque Limit Closed when current Torque
Limit is reached
5-30 Adv
026 Run Cmd is input Closed when either a Fwd or
Rev Run Command is active
-- Adv
027 Load Check Det Closed when Load Check
detected
5-22 Adv
029 Upper Limit Closed when Upper Limit-
SLOW DOWN or Upper Limit
STOP is input
5-20 Adv
02A During Run1 Closed when the Inverter
Outputting Voltage
-- Adv
02B During Fast Stop Closed During Fast Stop -- Adv
02F Load Weakening Closed during Load
Weakening
5-12 Adv
030 Lower Limit Closed when Lower Limit-
SLOW DOWN or Lower Limit
STOP is input
5-20 Adv
031 Upper/Lower Limit Closed when Upper Limit-
SLOW DOWN or Upper Limit
STOP or Lower Limit-SLOW
DOWN or Lower Limit STOP
is input
5-20 Adv
035 Load Check Alarm
Detection
Output will close when a
Load Check condition is
detected
-- Adv
037 Maintenance Closed when the timer
reaches C12.02
5-32
039 Drive Enable Closed when drive enable is
active
-- Adv
03A Overheat Pre Alarm
Time Limit
Closed when OH Pre Alarm
Time Limit is reached
5-77 Adv
03DDuring Speed Search Closed during Speed Search -- Adv
Parameter
Code Name Function
Reference
Page
Number Range
Initial
Value
Access
Level