IMPULSE•G+ Mini Advanced Instruction Manual – March 2014
5-53
03F Klixon Closed when MFDI 56 or 57
is on - motor is overheating
5-21 Adv
040 ~ FF Fault
Annunciate
Closed on specific faults -- Adv
101 Inverse Zero Speed Open when the output
frequency is below B02.02 or
D01.01
-- Basic/Adv
102 Inverse Frequency
Agree 1
Open when Frequency
Reference and Frequency
Output agree
-- Adv
103 Inverse Frequency
Set 1
Open when Output Frequency
Reference equals L04.01
5-72 Adv
104 Inverse Freq Detect 1 Open when output frequency
is < L04.01.
5-72 Basic/Adv
105 Inverse Freq Detect 2 Open when output frequency
is > L04.01.
5-72 Basic/Adv
106 Inverse Inverter
Ready
Open when an inverter is not
in a fault state
-- Adv
107 Inverse DC Bus
Undervolt
Open when DC Bus voltage
drops below UV trip point
-- Adv
108 Inverse Baseblock
N.O.
Open when the inverter is not
outputting voltage
-- Adv
109 Inverse Frequency
Reference Source
Open when the frequency
reference is input from the
digital operator (O02.01)
5-87 Adv
10A Inverse Local
Operation
Open when the RUN
command is input from the
digital operator
-- Adv
10B Inverse Trq Det 1
N.O.
Open when torque > L06.02 5-75 Basic/Adv
10DInverse DB Overheat Open when inverter displays
“RH” or “RR” fault
-- Adv
10E Inverse Fault Open during a major fault -- Basic/Adv
110 Inverse Minor Fault Open during minor fault or
alarm
-- Adv
111 Inverse Reset
Command Active
Open when a reset command
is present on the terminals
-- Adv
112 Inverse Timer Output See Timer function output 5-32 Adv
113 Inverse Freq Agree 2 Open when output frequency
= frequency reference
5-72 Adv
114 Inverse Frq Set 2 Open when output frequency
= L04.03
5-72 Adv
115 Inverse Frequency
Detect 3
Open when output frequency
L04.03
5-72 Adv
116 Inverse Frequency
Detect 4
Open when output frequency
L04.03
5-72 Adv
117 Inverse Torque Detect
1 N.C.
Closed when torque > L06.02
for longer than L06.03 time
5-73 Basic/Adv
118 Inverse Torque Detect
2 N.O.
Open when torque > L06.05 5-76 Adv
119 Inverse Torque Detect
2 N.C.
Closed when torque > L06.05 5-76 Adv
11A Inverse Forward
Direction
Open when running FWD/UP -- Adv
Parameter
Code Name Function
Reference
Page
Number Range
Initial
Value
Access
Level