3-149
RT9150E OPERATOR MANUAL OPERATING CONTROLS AND PROCEDURES
Published 2-23-2017, Control # 644-00
The emergency program is active if:
• The symbol (2) is displayed and
• the display (1) is shown; a time span of about 360
seconds elapses.
The telescoping mechanism can be operated with the
emergency program within this time.
After this time has elapsed, the symbol (3) appears, and you
need to restart the emergency program.
Determining the Type of Error
Refer to Figure 3-179.
Check which emergency program procedure is suitable for
the current error:
• If the display (1) shows no value, there is an error on the
length indicator.
• If a symbol (2) is violet, there is an error on the proximity
switch.
• The buttons next to the symbols (3) are active.
After pressing the button, locking or unlocking is
performed immediately.
NOTE: Note down the error code (4) first if you intend to
contact Crane Care before carrying out the
emergency program.
CAUTION
Equipment Damage Hazard!
In emergency mode, there is no monitoring of
prerequisites; functions are performed immediately after
pressing a button.
Ensure you constantly monitor the status of the
telescoping mechanism before you initiate locking or
unlocking.