3-37
RT9150E OPERATOR MANUAL OPERATING CONTROLS AND PROCEDURES
Published 2-23-2017, Control # 644-00
Telescope Mechanism Error Messages
If ECOS disables the telescoping mechanism, the following
display (Figure 3-22) is shown in the Telescope submenu.
• All the symbols (3) for telescope operation disappear
and the corresponding buttons are disabled.
• The display (1) appears.
• An error code (2) is displayed.
NOTE: Always note down this error code before contacting
Crane Care.
The display (1) shows the following symbols for the current
status:
Waiting
The symbol usually disappears shortly after
switching on the ignition.
If the symbol does not go out or is displayed
while operating the crane, this may be due to
an RCL shutdown or blown F3-3 fuse. Contact
Crane Care if these causes do not apply.
Telescope status divergence
ECOS has detected a difference between the
displayed and the current telescope status.
Enter the current telescope status, refer to
Entering the Current Telescope Status, page
3-60
Emergency program access
The telescoping mechanism can only be
operated with the emergency program, refer to
Telescope Emergency Program, page 3-147.
Emergency program
The Telescoping emergency program is open,
refer to Telescope Emergency Program, page
3-147.
Not active
Contact Crane Care if this status is still
displayed after repeatedly switching on the
ignition.
Reference Only