5-9
RT9150E OPERATOR MANUAL LUBRICATION
5
Published 2-23-2017, Control # 644-00
Grove
Item
Lube Point
Description
Figure
No.
Approved
Lubricant
Lube
Capacity
Lube Interval Application
Axles
11 Differentials Figure 5-2
GL-5
Extended
Service Interval
Gear Lubricant
6829012964
72 pints
(34 liters)
Check level every
500 hours or 3
months
Drain and fill every
4000 hours or 2
years
Fill to bottom of hole
in housing on the
steer cylinder side (2
places)
NOTE: Lube level close enough to the hole to be seen or touched is not sufficient. It must be level with the hole.
When checking lube level, also check and clean housing breathers.
CAUTION: Use of non semi-synthetic lubricant may damage components and/or invalidate published lubricant intervals.
CAUTION: If the makeup amount is substantially more than 0.23 liter (0.5 pint), check for leaks.
12
Planetary Hubs
and Wheel
Bearings
Figure 5-2
GL-5
Extended
Service Interval
Gear Lubricant
6829012964
30 pints
(14.2 liters)
Check level every
500 hours or 3
months
Drain and fill every
4000 hours or 2
years
Fill to the bottom of
the level hole in the
housing with the fill
plug and the oil level
mark horizontal (4
places)
CAUTION: Use of non synthetic lubricant may damage components and/or invalidate published lubricant intervals.
Reference Only

Table of Contents

Other manuals for Manitowoc Grove RT9150E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove RT9150E and is the answer not in the manual?

Manitowoc Grove RT9150E Specifications

General IconGeneral
BrandManitowoc
ModelGrove RT9150E
CategoryConstruction Equipment
LanguageEnglish

Related product manuals