VI. MAINTENANCE
6.1. Hydrostatic transmission
6.1.1. Filtration Filtration
Suction filter between the tank and pump.
In normal operating conditions, the filter ① must be replaced at the following intervals:
50 operating hours after initial start-up
1
400 operating hours after initial start-up
And then: refer to the maintenance log for the M24D Hellios
Filter cartridge reference: 161 209 000
The filter cartridge must be changed with the combustion engine stopped.
To replace the cartridge:
◦ unscrew the cartridge using a strap wrench,
◦ clean the surface of the filter casing seal,
◦ fill the cartridge with fresh oil,
◦ rescrew the new cartridge on firmly (add oil to the seal).
Only original MATROT ÉQUIPEMENTS parts are covered by the warranty of your self-propelled
machine.
1
e self-propelled machine is delivered with a lter cartridge with a life cycle of 50 hours.
Filling of the
hydraulic fluid tank
Minimum level
detection probe
Hydraulic fluid level