Chapter 5 Parameters
64
Para
meter
Name Range
Default
value
Unit
P110 Digital input DI1 filter 0.1~100.0 2.0 ms
P111 Digital input DI2 filter 0.1~100.0 2.0 ms
P112 Digital input DI3 filter 0.1~100.0 2.0 ms
P113 Digital input DI4 filter 0.1~100.0 2.0 ms
P114 Digital input DI5 filter 0.1~100.0 2.0 ms
P118 Digital high speed input 1 (HDI1) filter level 1~8 4
P119 Digital high speed input 2 (HDI2) filter level 1~8 4
P120 Digital input DI forced valid 1 00000~11111 00000
P121 Digital input DI forced valid 2 00000~11111 00000
P122 Digital input DI forced valid 3 00000~11111 00000
P123 Digital input DI forced valid 4 00000~11111 00000
P124 Digital input DI forced valid 5 00000~11111 00000
P130 Digital output DO1 function -28~28 8
P131 Digital output DO2 function -28~28 0
P132 Digital output DO3 function -28~28 0
P133 Digital output DO4 function -28~28 0
P134 Digital output DO5 function -28~28 0
P149 Delay time of dynamic braking 0~1000 0 ms
P164 Emergency shutdown mode 0~1 0
P165 Motor static speed detection point 0~1000 5 r/min
P166 Motor static electromagnetic brake delay time 0~2000 150 ms
P167
Electromagnetic brake waiting time when the
motor is running
0~2000 500 ms
P168
Speed of action of electromagnetic brake
when the motor is running
0~3000 100 r/min
P169 Delay time of electromagnetic brake opening 0~1000 0 ms