Chapter 2 Wiring
24
2.2
Brake resistance adaptation
Drive series
Internal brake
resistance
specification
Recommended
specification for external
brake resistance
Minimum resistance
of external brake
resistance
AC220V
GL1A0 None 47Ω/100W 30Ω
GL1A8 47Ω/100W 36Ω/200W 30Ω
GL3A0 47Ω/100W 36Ω/200W 30Ω
GL5A5 47Ω/100W 36Ω/200W 25Ω
GL7A5 47Ω/100W 36Ω/200W 25Ω
GL120 47Ω/100W 25Ω/200W 20Ω
GL160 47Ω/100W 25Ω/200W 20Ω
GL190 47Ω/100W 20Ω/500W 12Ω
GL240 None 20Ω/500W 12Ω
AC380V
GH2A0 110Ω/100W 50Ω/500W 45Ω
GH3A5 110Ω/100W 50Ω/500W 45Ω
GH5A4 110Ω/100W 50Ω/500W 45Ω
GH8A5 47Ω/100W 50Ω/500W 40Ω
GH130 47Ω/100W 36Ω/750W 30Ω
GH170 None 36Ω/750W 30Ω
GH210 None 20Ω/1000W 15Ω
GH260 None 20Ω/1000W 15Ω
GH320 None 20Ω/1000W 15Ω
GH390 None 20Ω/1000W 12Ω
Note 1 The resistances recommended in the table can be used in most applications. In practical
application, if the demand cannot be met, please contact the manufacturer.
Note 2. When all drivers are changed to external brake resistance, parameters P084/P085/P086
should be modified accordingly. Refer to the corresponding parameter description in
section 5.4.1 for specific modification.