50
Fault Code Overview (continued)
CODE MESSAGE FAILURE FAULT OCCURRENCE ACTION
E80
SoapTimeOut Incorrect signal for liquid
detergent dispensing
Whole cycle Full Stop + Tumble
E81
No Reheat Heating failure Wash step (traceability only) Full Stop + Tumble
E82
No Refill Refill failure Wash step (traceability only) Full Stop + Request for Continue
E83
Power Interruption No successful wash cycle
termination
Abnormal cycle termination
(traceability only)
Re-enter wash cycle selections
E85
RTC Reset Bat Real time clock, no battery
or battery low power
End cycle (traceability only) For information only
E100
Weigh No Comm Communication fault
weighing system
(models with weighing
system only)
Full Stop + Tumble
E101
Weigh Low Washer weight too low (models with weighing
system only)
Do not start
E102
Weigh High Washer weight too high (models with weighing
system only)
Do not start
E103
Weigh Balance Weight not balanced over
4 load cells
(models with weighing
system only)
Do not start
E104
Weigh Overload Weight on individual load cell
exceeds maximum
(models with weighing
system only)
Full Stop + Tumble
E105
Weigh Airbags No functional air pressure
system
(models with weighing
system only)
Do not start
E300–
E353
MITS ERR Specific Mitsubishi inverter
alarm
Whole cycle Full Stop + Safety Time
E500–
E525
MEMORY ERR Memory error Any time Full Stop + Safety Time
E550
TRACEABILITY
WRITE
Internal memory error data
for traceability
Traceability function,
whole cycle
For information only
E551
TRACEABILITY
FULL
Internal traceability memory
is full
Traceability function,
whole cycle
For information only
E560–
E563
USB ERRORS Errors in communication
with USB flash disk
Only in advanced menu
data export/import
For information only
E600–
E628
SOFTW. ERR Software error Any time Full Stop + Safety Time