21 INSTALLATION AND CONFIGURATION
3021M100-002
21-5
21.3 Standard I/O Card Installation
Standard I/O cards are defined as cards which use only the 120-pin edge connector
for mounting into the motherboard expansion slot. Standard I/O cards include:
Multi I/O*
V.24 Serial I/O*
V.35EU Serial I/O*
V.35H Serial I/O*
X.21 Serial I/O*
Universal I/O*
CSU/DSU I/O*
ISDN-U I/O
ISDN-S/T I/O
DDVC**
V.34 Modem*
T1/E1 I/O*
DIM I/O
Ethernet LAN I/O
Fast Ethernet LAN I/O
Token Ring I/O
* A Serial Expansion Module (SEM) is required if you are installing this card in slot
5-8.
**The Dual Digital Voice Compression (DDVC) card is not considered an I/O card,
although it occupies an I/O card slot. This card is used with the ISDN S/T
I/O card.
Procedure 4: Installing the Serial Expansion Module
This procedure assumes that you have installed or will install an I/O card in any of
slots 5 to 8 which requires a SEM.
This procedure assumes that you have removed the cover from the chassis
(Procedure 2).
To install the SEM:
1. Remove the SEM from its packaging.