Operation
optoNCDT 1402
Output Scaling via the “Select“ Key6.2.1
Key
select
LED
Measuring
Green, red, yellow,
depends on
measuring position
Color according
to measuring
position
flashes red
approx. 2 Hz
flashes green
approx. 2 Hz
Start
teaching
Position the
measuring
object to 4 mA
Position the
measuring
object to 20 mA
Teach-in 1 Teach-in 2 Measuring
red
t
0
x5 min 2 s x30 s x30 st
1
t
2
t
3
t
4
t
6
t
7
t
8
t
5
yellow yellow
min.
30 ms
min.
30 ms
Timing for the output scalingFig. 9:
The scaling is also available via the software tool.
Key
select
LED
Measuring
Green, red, yellow,
depends on
measuring position
Color according
to measuring
position
flashes red approx. 2 Hz
Hold the key
Measuring
red
t
0
x5 min 2 s 2 s5 st
1
t
2
t
3
t
4
yellow
Timing for the reset of the output scalingFig. 10: