Page 69
Instructions for Operating
optoNCDT 1402
Instructions for Operating 9.
Reflection Factor of the Target Surface9.1
In principle the sensor evaluates the diffuse part of the reflected laser light (see Fig. 21).
Laser beam
Ideal diffuse reflection Real reflecionDirect mirror
reflecion
Laser beam
Laser beam
D
2D
Reflection factor of the target surface Fig. 21:
A statement concerning a minimum reflectance is difficult to make, because even a small diffuse fraction can
be evaluated from highly reflecting surfaces. This is done by determining the intensity of the diffuse reflection
from the CCD array signal in real time and subsequent compensation for intensity fluctuations, see Chap. 3.2.
Dark or shiny objects being measured, e.g. black rubber, may require longer exposure times. The exposure
time is dependent on the measurement rate and can only be increased by reducing the sensor’s measure-
ment rate.
Error Influences9.2
Light from other Sources 9.2.1
Thanks to their integrated optical interference filters the optoNCDT1402 sensors offer outstanding perfor-
mance in suppressing light from other sources. However, this does not preclude the possibility of interference
from other light sources if the objects being measured are shiny and if lower measurement frequencies are
selected. Should this be the case it is recommended that suitable shields be used to screen the other light
sources. This applies in particular to measurement work performed in close proximity to welding equipment.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MICRO-EPSILON ILD1402-5 and is the answer not in the manual?

MICRO-EPSILON ILD1402-5 Specifications

General IconGeneral
BrandMICRO-EPSILON
ModelILD1402-5
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals