Serial Interface RS422
optoNCDT 1402
Error code
Description Bytes Value
Command error 1 2
Faulty number of parameters 1 3
Time out 1 4
Overview of Commands8.2.2
Information commands
0x0900 VERSION Shows the software version
0x0C00 INFO Shows the sensor data
Filter
0x1001 MEDIAN Median filter over 3 values, on/off
Measurement value output
0x0E01 OUTPUTCHANNEL Output analog / digital
Error output (analog output)
0x0F01 SAVELASTMV Behavior of the analog output in case of er-
rors
Reset
0x0100 BOOT Reboots the sensor
Switch data protocol ILD1401 / ILD1402
0x1100 SET_CIMODE_1402 Sensor operates with data protocol ILD1402