EasyManuals Logo

MIMAKI CG-AR Series User Manual

MIMAKI CG-AR Series
184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #88 background imageLoading...
Page #88 background image
Chapter 3 Cutting Data with Register Marks
88
Setting Details
reading resumes.
Register mark detection start position
Set to [OFF] if checking is not required.
l
Detection mode setting [DETECT MODE]
Setting Details
High Speed
(FAST)
Register mark lines are scanned bi-directionally to determine the position.
Detection time is reduced, but accuracy is also reduced.
Precision
(PREC)
Register mark lines are scanned bi-directionally and then re-scanned from a distance
before and after the lines to match the speed for response and determine the position
accurately.
Detection time increases, but accuracy also increases.
l
Sensor sensitivity setting [SENSOR LEVEL]
Setting Details
1 to 7 Check the sensitivity of the register mark sensor. Normally, set this to "4".
If it cannot detect the register marks: Increase sensitivity.
If it mis-detects the register marks: Decrease sensitivity.
l
Filled-in register mark setting [MARK FILL UP]
Setting Details
ON, OFF Set to [ON] when detecting register marks printed using the "Fill around the register
mark" function.
If the "Fill around the register mark" function is used, the register marks should be at
least 10 mm in size.
l
DATA ID CODE
Setting Details
ON, OFF Set to [ON] when detecting register marks with an ID printed using the "ID Cut" function.
"ID Cut Process"(P. 97)

Table of Contents

Other manuals for MIMAKI CG-AR Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MIMAKI CG-AR Series and is the answer not in the manual?

MIMAKI CG-AR Series Specifications

General IconGeneral
BrandMIMAKI
ModelCG-AR Series
CategoryPlotter
LanguageEnglish

Related product manuals