Chapter 8 Dealing with Problems
170
Error
number
Message Cause Corrective action
C61 Pen Stroke • The pen height is
incorrect.
Check the following points:
• Make sure the pen line rubber is not
worn or deformed and remains intact.
• Check to confirm nothing adheres to
the pen line rubber.
• After installing the pen in a
commercially available pen holder,
check to confirm the installed position
is correct.
Display Message List
These are messages displayed in remote mode.
They are not error messages, but take the appropriate action as necessary.
Message Cause Corrective action
** OFFSCALE ** • The cutting data extends
beyond the available cutting
area. Or, the sheet was cut
correctly to the end and then
stopped.
• Either increase the sheet size or reduce
the data size. Or, use the divided cutting
function.
** NO SHEET ** • No sheet is loaded, or a
transparent sheet is loaded.
• Load a sheet. Or disable the sheet sensor.
** VIEW ** • NOT-READY (NR;) was
received from the host
computer, and the machine is
in local mode.
• Perform the necessary options such as
sheet detection and origin setting, then
press the [REMOTE] key to select remote
mode.
** DIGITIZE ** • The digitize command (DP;)
was received from the host
computer, and the machine is
in digitize mode.
• Move the pen nib as necessary, then
press the [REMOTE] key.
• To cancel digitize mode, use the
[FUNCTION] key to clear the data.
** END COPY ** • The received data contains
an origin update command
(ZT;, !PG;), and the process
ended after one copy.
• Multiple sheet cutting is not possible.
• Reset the host computer to perform
multiple sheet cutting.
* DIVISION * 5s • The machine is waiting for
the next data after cutting
data exceeding the sheet
width when using divided
cutting.
• If data from the host computer is not
received for 10 seconds, this is recognized
as a data division. Frame cutting and mark
cutting are then performed, and the
machine switches to local mode.
* END DIVISION * Displayed in the following
situations:
• When data is received
containing the origin update
command (ZT;,!PG;)
• When the sheet width does
not exceed 1 cm
• When the sample cut
exceeds the sheet width
• When 2-point line correction
is enabled
• Divided cutting is not possible.