EasyManua.ls Logo

MIMAKI JFX200-2531 - MBIS Maintenance; Cleaning the LM Guide

MIMAKI JFX200-2531
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance
4-3
1
1
1
4
Routine Maintenance
MBIS Maintenance
There is a cotton pad attached to the cap wiper section on the rear of the tank that is used to wipe off any ink
adhering to the underside of the cap when replacing ink bottles of the MBIS. Periodically replace the cotton
pad. (Recommended replacement period: Once every two weeks or once every fifth time bottles are replaced.)
1
Loosen the screw.
2
While pressing A part, lift up B part as shown in
the figure on the right.
3
Replace the Cotton pad.
Insert the cotton pad until the section indicated by the dotted line in the figure below.
4
Fixing the screw.
Cleaning the LM guide
When the LM guide gets dirty, wipe the LM guide with soft cloth.
Screw
New cotton
pad
Insert until
here.
LM guide

Table of Contents

Other manuals for MIMAKI JFX200-2531

Related product manuals