Exchange the flushing filter
4-37
1
1
1
4
Routine Maintenance
Replacing the flushing filter before the replacement message is displayed
1
Select [STATION] of the maintenance menu.
(1) Press the key in LOCAL.
(2) Press to select [MAINTENANCE] and press the key.
(3) Press to select [STATION].
(4) Press the key.
2
Press to select [FLUSHING FILTER].
3
Press the key.
4
Press the key.
5
Excahange the flushing filter, and then press the
key.
• The carriage will return to the station, and the mode will
return to LOCAL.
• Until filter exchange is competed,
[COMPLETED [ENT]]
is displayed on the screen. After the
work up to the step 5 is completed, press the key. If you press the key
before exchange is completed, the machine moves to the next procedure.
STAT I ON
FLUSHING F I LTER[ ENT ]
CARR I AGE OUT
START [ ENT ]
EXCANGE
COMP L ET ED [ ENT ]