Troubleshooting
5-8
7
Press the key.
• The error is released and the negative pressure control starts.
If PL ENC SNS(L)/(R) occurs
PL ENC SNS(L)/(R) error indicates poor sensitivity of the encoder used to correct travel distance in the feeding
direction.
When this error occurs, restart the printer.
If this error occurs again after restart, contact your local distributor to call for service.
The image quality may lower before the service engineer arrives. In this case, you can perform printing by
setting [MACHINE SETUP]/[PRINT MODE] to [PRIORITY:SPEED].
For the setting procedure, refer to
P. 3 - 44
"Setting Print Mode".
• When an error occurs even after you adjusted the pressure, contact your local distributor to call for
service.