5-12
Error messages
When an error message is displayed, eliminate the error according to the chart below.
If the same error message appears again, contact your dealer or an office of MIMAKI to call for service.
Message Cause Solution
There is an abnormality in the parame-
ters.
Turn off the power to the machine and turn
it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
Head connection can not be confirmed.
Head temperature can not be read.
An abnormality occurred in the ink dis-
charge waveform.
Abnormality of the Driver of the Print
head.
There is no PRAM.
Data transmission speed is too fast.
Control circuit board is defective.
Data transmission speed is too slow.
Control circuit board is defective.
The battery life end of the internal clock
is detected.
Contact your local distributor to call for ser-
vice.
Head data transferring sequence error
occurred.
Turn off the power to the machine and turn
it on after a while.
If the same error message appears again,
contact your local distributor to call for ser-
vice.
Sequential number abnormality of the
event log occurred.
An error occurred in the main PCB
1.2V power supply.
An error occurred in the main PCB
2.5V power supply.
An error occurred in the main PCB
3.3V power supply.
An error occurred in the main PCB 5V
power supply.
An error occurred in the main PCB 35-
1 power supply.
An error occurred in the main PCB 5VB
power supply.
An error occurred in the main PCB VTT
power supply.
ERROR 0 4
PARAM ROM
ERROR 1 0 8
HD CONNECT [ 12345678 ]
ERROR 1 0 8
HD THERMIS[ 12345678 ]
ERROR 1 2 a
HDC SPEED
ERROR 1 2 e
Head Fa i l ed [ xxxx ]
ERROR 1 2 2
CHECK : SDRAM
ERROR 1 2 8
HDC F I FO OVER
ERROR 1 2 8
HDC F I FO UNDER
ERROR 1 2 9
BATTERY EXCHANGE
ERROR 1 3 0
HD DATA SEQ
ERROR 1 4 8
E-LOG SEQ
ERROR 1 5 1
Ma i n PCB V1 2R
ERROR 1 5 2
Ma i n PCB V2R5
ERROR 1 5 3
Ma i n PCB V3R3
ERROR 1 5 4
Ma i n PCB V0 5
ERROR 1 5 5
Ma i n PCB V3 5 - 1
ERROR 1 5 6
Ma i n PCB V5B
ERROR 1 5 7
Ma i n PCB VTT