Ionizer maintenance
4-44
This ionizer has the function to output alarms.
Alarm output part
Alarm function
Alarm output function
Item Alarm (ALM) Ion level (ION) Condition (COND)
Indication
Indicator light blinks three times
about every second.
Indicator light blinks twice about
every second.
Indicator light blinks. once about
every second
Status etc.
Internal circuit has been broken.
Abnormal discharge occurs.
Due to blot on the electrode
probe and wear of it, ion
production has decreased.
Use this as a guide for time to
take care of the electrode probe.
The installed environment
(temperature, humidity, peripheral
metals, etc.) have affected the
performance to remove electricity.
Removing
electricity
Removing electricity stops. Removing electricity continues. Removing electricity continues.
Countermeasure
Contact a distributor in your
district or our office.
Take care of the electrode
probe.
*1
If the status cannot be improved,
replace the relevant electrode
probe.
*1. Before taking care of the electrode probe, turn off the main power of the main body, and be careful to perform the work.
Check the environment and
peripheral metals.
Replacement part
SPA-0208
Tungsten electrode probes for
ionizer (including 4)
Indicator light