Ionizer maintenance
4-43
1
1
1
4
Routine Maintenance
Installing the Filter
Explain how to replace the filter of Electrode Probe Cleaning Kit 2(SPA-0239).
1
Remove the used filter and insert the new filter
into the hole at the center of the electrode probe
cleaning kit 2.
• Be careful of the way the filter is facing. Install the filter with
the diagonally tip side up.
2
Push the filter using tweezers all the way into the
electrode probe cleaning kit 2.
• Mounting position of the filter to be set between 0 to 2mm to
the end faces.
• Push the filter completely inside to prevent it from bending.
Cleaning Kit 2 Replacement Filter
• After the filter is used to clean multiple electrode probes, dust becomes attached to the filter and the
cleaning abilities are reduced.
• If the filter is dirty, replace with Electrode Probe Cleaning Kit 2 included instead filter or exchange for
optional cleaning kit of filters, (SPC-0240).
Soak the Cleaning Kit
• Lids are included with the cleaning kit 2 to prevent dust from entering the cleaning
kit 2 during storage. Always put the lids on when storing.
• Also, a cord can be passed through the strap hole so that the kit can be hung on a
wall. Be sure to put on the lids during this storage method as well.
Purchase a strap separately.
Cleaning Kit Replacement Filter
• After the filter is used to clean multiple electrode probes, dust becomes attached
to the filter and the cleaning abilities are reduced.
• When grime becomes attached to the filter, replacement it with an electrode probe
cleaning kit replacement filter (SPC-0238). (sold separately)