If an error related to the sub tank occurs (Error 618 to 61b)
The Error 618 to 61b are related to the sub tank.
Execute following procedures when an error about sub tank occurs, or when the nozzle is not unclogged after
cleaning.
1
Select [SUB TANK] of the maintenance menu.
(1) Press the key in LOCAL.
(2) Press to select [MAINTENANCE] and press the key.
(3) Press to select [SUB TANK].
2
Press the key.
3
Press and select a sub tank to
be maintained.
: Select a sub tank.
: Select whether you perform maintenance or not.
If Error 61b occurs, an appropriate head is selected. Press
key.
4
Press the key.
5
Press the key.
The automatic discharging operation and the filling operation are
performed.
Then, cleaning is performed.
6
Press the key several times to end the setting.
SELECT SUBTANK
:MMKKCCYY
SELECT SUBTANK
:MMCC____
SUB TANK
EXECUTE [ ENT ]
** FILL UP **
PLEASE WA I T
** CLEANING **
PLEASE WA I T