Clean the electrode inner wall
Electrode Probe Cleaning Kit 2 (SPA-0239) is used to clean the inner wall of the electrode probe cap.
When clean the tip of the electrode Probe, please use Electrode Cleaning Kit (SPA-0237).
1
Soak the filter of electrode probe cleaning kit 2
for the cleaning unit in alcohol.
2
Cover the electrode probe cleaning kit 2, and
gently turn two or three times.
• The filter of electrode probe cleaning kit 2 wipes away stains
on the electrode probe.
• If it is very dirty, replace the filter and clean it again.
Tools required for
maintenance
• Electrode Probe Cleaning Kit 2 (SPA-0239)
• Alcohol • Gloves • Goggles
• Do not touch the electrode probe directly. You may get injured. Be careful to work.
• Do not touch the electrode probe with a hard thing such as a tool. It may cause an accident or failure
of the machine.