40
Procedures
3
Press the key.
The “TARE” mode can be entered.
The display on the load display section will show
“ZERO”.
Press the key.
The display of “ZERO” on the load display
section will flash on and off, and Tare weight
cancellation will be entered.
Warning At the same time, care should
be taken not to apply load variation due to
vibration and so on.
If load variation is applied, zero point
becomes unstable, so there is a possibility
that correct zero can’t be read.
4
When completed, the indication of load
display will show “END”.
However, when the initial load isn’t entered
within the range of 0.3 mV/V and 2.4 mV/V,
the error code in the right will be shown for
about 2 seconds, then the display on the load
display will show “TARE”, and returns to the
step 2.
TELZero point OVER
TEHZero point OVER
Error code
Error code
Press the key.
After quitting from the “TARE” mode, the load
di l
ill
h
th
t
ld
l
5
display will sho
w
th
e
present load value.