82
8−2. Function of Function data
D F−01 Selection of decimal point at display position
Initial value=00000 00000=Non
00001=10
1
00002=10
2
00003=10
3
00004=10
4
D F−03 Selection of display rate
Initial value=00000 00000=4 times/s
00001=20 times/s
D F−04 Setting digital filter
Initial value=00003 Setting range:=00000〜00008, Average of 2
(n)
times
※Select the average times for digital filter. When the figure grows larger, the filter will
become stronger, then effects from vibrations and so on are shown scarcely on the
display. However, if too large figure is selected, the response to variation of input
sensor will become worse.
※Using the digital filter where vibrations and so on may exist is effective for removing
the deflection on the display.
D F−06 Setting key lock
Initial value=00000 10
0
digit :ON/OFF of CHECK value(Press the key in the
condition of pressing
key.)
10
1
digit :ON/OFF of Peak Hold function, A/Z ON(),
Reset of the peak value, A/Z OFF(
)
10
2
digit :Reading out the change mode of S1 setting(),
Reading out the change mode of S2 setting(
)
10
3
digit :Execute the zero setting(Press the key
in the condition of pressing the
key.)
10
4
digit :Reading out the function mode()
※The setting of “0” makes the lock OFF of key function, and the setting of “1” makes
the lock ON of key function. Moreover, when the reading out the function mode is
locked, the function mode can be proceeded after pressing the
key for over 2
seconds in the condition of pressing the
key for over 1 second.
D F−08 Setting zero tracking data width
Initial value=00000 00000=Zero tracking OFF
Setting range:00000〜00099
Unit:0.5D
Data width of 49.5D with the setting “00099”.
※Effective only when the value of 00001〜00099 is set with the F−07.