120
3 CONFIGURATION OF INSTRUCTIONS
3.8 Counting Step Number
*1 If the same device is used for (S1) and (S2), the number of basic steps increases by one.
*2 The number of steps decreases with a standard device register.
*3 Not available with LCPU.
When multiple standard device registers are used in an instruction applicable to subset processing, the number of steps
decreases.
The following table shows the number of steps for each instruction.
*4 If the same device is used for (S1) and (D), the number of basic steps increases by one.
DMOV, DMOVP, EMOV, EMOVP Serial number access format file register, Extended data
register (D), Extended link register (W)
12
Multiple CPU shared device
*3
Decimal constant, hexadecimal constant, real constant
BCD, BCDP, BIN, BINP, FLT, FLTP, CML, CMLP Serial number access format file register, Extended data
register (D), Extended link register (W)
(S): 1, (D): 2 2
Multiple CPU shared device
*3
DBCD, DBCDP, DBIN, DBINP, INT, INTP, DINT,
DINTP, DFLT, DFLTP, DCML, DCMLP
Serial number access format file register, Extended data
register (D), Extended link register (W)
(S): 1, (D): 2 2
Multiple CPU shared device
*3
Decimal constant, hexadecimal constant, real constant (S): 1
Instruction symbol Locations where standard device register is
used
Added steps
(number of
instruction
steps)
Number of basic
steps
LD=, LD<>, LD<, LD<=, LD>, LD>=, AND=,
AND<>, AND<, AND<=, AND>, AND>=, OR=,
OR<>, OR<, OR<=, OR>, OR>=, LDD=,
LDD<>, LDD<, LDD<=, LDD>, LDD>=, ANDD=,
ANDD<>, ANDD<, ANDD<=, ANDD>, AND>=,
ORD=, ORD<>, ORD<, ORD<=, ORD>,
ORD>=
(S1) and (S2) -2(1) 3
+, -, +P, -P, D+, D-, D+P, D-P, WAND, WOR,
WXOR, WXNR, DAND, DOR, DXOR, DXNR,
WANDP, WORP, WXORP, WXNRP, DANDP,
DORP, DXORP, DXNRP (2 devices)
(S) and (D) -2(1) 3
+, -, +P, -P, D+, D-, D+P, D-P, WAND, WOR,
WXOR, WXNR, DAND, DOR, DXOR, DXNR,
WANDP, WORP, WXORP, WXNRP, DANDP,
DORP, DXORP, DXNRP (3 devices)
*4
(S1), (S2), and (D) -2(1) 3
(S1), or (S2) and (D) -1(2)
(S1) and (S2)
(only when that device that the number of steps does not
increase is specified for (D))
0(3)
(S1) and (S2)
(only when a serial number access format file register is
specified for (D))
+2(5)
*, *P, /, /P (S1), (S2), and (D) -2(1) 3
(S1), or (S2) and (D) -1(2)
D*, D*P, D/, D/P, E*, E*P (S1), (S2), and (D) -2(1) 3
(S1), or (S2) and (D) -1(2)
(S1) and (S2)
(only when that device that the number of steps does not
increase is specified for (D))
0(3)
(S1) and (S2)
(only when a serial number access format file register is
specified for (D))
+2(5)
MOV, MOVP, DMOV, DMOVP, EMOV, EMOVP (S) and (D) -1(1) 2
BCD, BCDP, BIN, BINP, DBCD, DBCDP, DBIN,
DBINP, FLT, FLTP, DFLT, DFLTP, INT, INTP,
DINT, DINTP, CML, CMLP, DCML, DCMLP
(S) and (D) -1(1) 2
Instruction symbol Devices with additional steps Added steps
(number of
instruction
steps)
Number of basic
steps

Table of Contents

Related product manuals