786
7 APPLICATION INSTRUCTIONS
7.19 Other Instructions
Below is the method for calculating the file size (total number of bytes) when a CSV format file is written to the ATA card.
*4 For all lines but the final line, this is the specified number of columns. The number of columns on the final line depends on the number of
columns specified via the amount of data written. It is calculated as follows.
*5 The number of bytes for each data value is calculated as shown below.
Operation error
In any of the following cases, an operation error occurs, the error flag (SM0) turns ON, and an error code is stored into SD0.
Total number of bytes = Total bytes excluding final line + bytes of final line
(Number of bytes on a line = number of columns
*4
+ 1 + total bytes of all data values on line
*5
)
The number of lines excluding the final line is calculated. (Number of lines excluding final line = Amount of data in write request number of columns
(remainders discarded))
The number of columns in the final line is calculated. Number of columns in final line = Amount of data in write request - number of lines excluding final
line number of columns)
Sign of data value Bytes per data value Byte count range Examples
Positive Num. digits 1 to 5 (word specified)
1 to 3 (byte specified)
12345: 5 bytes
67: 2 bytes
Negative Num. digits + 1 2 to 6 (word specified)
2 to 4 (byte specified)
-12345: 6 bytes
-67: 3 bytes
Error
code
Error details Q00J/
Q00/
Q01
QnH QnPH QnPRH QnU LCPU
4004 The device that cannot be specified has been specified. 
4100 Values specified in control data (D0) and the subsequent devices are out of
the setting range.
No space is found when a new file is created.
A value that cannot be used has been set for the file name (S1).
The attribute of the file name (S1) is "read only".

The drive specified by drive designation device (S0) contains the medium
other than the ATA card.
Space in the ATA card is insufficient.
An access error occurred in the ATA card.

The drive specified by drive designation device (S0) contains the medium
other than the SD Memory card.
Space in the SD Memory card is insufficient.
An access error occurred in the SD Memory card.

If the instruction accesses a file which has been accessed by another
function

If the instruction writes data into an SD memory card with the write protect
switch enabled (write inhibited)

4101 The value specified in "No. of request write data" (S2) is out of the setting
range, or exceeds the device range specified in ((S2)+1) or the subsequent
devices.

The range of the device specified in (D0) or (D1) exceeds that of the
corresponding device.


Table of Contents