EasyManuals Logo

Mitsubishi F700 Series User Manual

Mitsubishi F700 Series
408 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #367 background imageLoading...
Page #367 background image
356
Inspection item
Reinstallation (00083 to 03610)
1)After confirming the orientation of the fan, reinstall the fan so that the arrow on the left of "AIR FLOW" faces up.
2)Reconnect the fan connectors.
3)Reinstall the fan cover.
<Fan side face>
AIR FLOW
00083, 00126
00170 to 00380
00470, 00620
00770 to 03610
2. Insert hooks until
you hear a click
sound.
1. Insert hooks into
holes.
00083, 00126
2. Insert hooks until
you hear a click
sound.
1. Insert hooks into
holes.
00170 to 00620
2. Insert hooks until
you hear a click
sound.
1. Insert hooks into
holes.
00770 to 03610
CAUTION

Installing the fan in the opposite air flow direction can cause the inverter life to be shorter.
When installing the fan, use care to prevent wires from being caught between the inverter and fan.
Switch the power off before replacing fans. Since the inverter circuits are charged with voltage even after power off,
replace fans only when the inverter cover is on the inverter to prevent an electric shock accident.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi F700 Series and is the answer not in the manual?

Mitsubishi F700 Series Specifications

General IconGeneral
Humidity95% RH or less (non-condensing)
Control MethodV/F control
Protection FeaturesOvercurrent, overvoltage, undervoltage, overheat, short circuit
Communication OptionsRS-485
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +65°C
AltitudeUp to 1000m above sea level
Overload Capacity150% for 60 seconds
Cooling MethodForced air cooling
Power Range0.75 to 630 kW (1 to 845 hp)
Output Voltage3-phase 200 to 240 VAC, 380 to 500 VAC (matching input voltage)